/Electricity
  • Converts standard Utility Pulsed Meters (Electric- Gas - Water) into Modbus Protocol. Ideal for both new installations or retro fitting Manufactured to ISOEN 15745 - 2 :2007. Data Sheets: Technical Data Installation Instructions - Gas Meter with Modbus Installation Instructions - Water Meter with Modbus
  • EM-735 S CT Meter

    £110.00 Ex VAT
    EM735 S CT Smart Meter Main Features & Functions Three phase metering • CE Approved • Three Phase metering, 7 din Modules • Accuracy class 1 according to IEC62053-21 • LCD display, 6 integer 2 decimal • Large clear backlight display • Energy consumption LED • Isolate pulse output • Internal transformer • Direct metering up to 100A, transformer metering 1.5(6)A • 27 CT rate can be selected • Optional single-phase Model • Can be set through front panel • Memory back-up (EEprom) Data Sheets EM735 M-Bus Manual
  • Single Phase 1 module energy meter with Serial Modbus interface 330mV CT ac input Main Features and Functions
    • Single phase metering • MID approved with module B & D certification. • Bidirectional energy metering 1 DIN modules,230V AC 50/ 60Hz. • Solid-core sensor &open-core sensor,330mV ac input 100A • Display of Voltage, Ampere, kW, PF, Hz, +kWh,-kWh,ΣkWh • Total energy usage can be calculated via 5 different modes. • Display Modbus RTU Interface data:baud rate, Modbus id, Parity • Reactive power and reactive energy available through interface • S0pulse output, transmission of measured values via pulses. • LCD display, 5 integer 1 decimal • Clear green backlight display • Accuracy class B according to EN50470-3
    •    Accuracy class 1 according to IEC62053-21 • Memory back-up (EEprom) • The meter is intended to be installed in a Mechanical Environment ‘M1’, with Shock and Vibrations of low significance, as per 2014/32/EU Directive and should be installed in Electromagnetic Environment ‘E2’, as per 2014/32/EU Directive.
    ** Please note :  pricing includes 1 x Split Core CT Data Sheets: Manual
  • EM415 Mb 10 (100)A LCD display Single DIN rail mounted M-Bus kwh Meter Main Functions & Features:
    • MID approved with appendix "B" and "D" certification
    • Single phase metering 4 din modules
    • Direct metering up to 100A
    • LCD display, 6 integer 1 decimal
    • Clear green backlight display
    • SO pulse output
    • Smart Communication port
    • M-Bus output
    • Accuracy class B according to EN50470-3
    • Accuracy class 1 according to IEC62053-21
    • Memory back-up (EEprom)
    Pulse Output Function:   The SmartLink meter is equipped with a pulse output which is fully separated from the inside circuit. Reading the Meter: The SmartLink energy meter is equipped with 6+1 LCD display, which is used as recording consumption and cannot be reset to zero.  The number system is based on units of 10.  Units are kWh. Communication: The SmartLink meter has M-Bus COM. Programming Function: With the buttons on the front panel, address, baud rate and passwords can be programmed. Data Sheets: Technical Manual
  • EM415 Mod 10 (100)A LCD display Single DIN rail mounted kwh Meter Main Functions & Features: MID approved with appendix "B" and "D" certification Single phase metering 4 din modules Direct metering up to 100A LCD display, 6 integer 1 decimal Clear green backlight display SO pulse output Smart Communication port Modbus RTU with 16 bit CRC Accuracy class B according to EN50470-3 Accuracy class 1 according to IEC62053-21 Memory back-up (EEprom) Pulse Output Function:   The SmartLink meter is equipped with a pulse output which is fully separated from the inside circuit. Reading the Meter: The SmartLink energy meter is equipped with 6+1 LCD display, which is used as recording consumption and cannot be reset to zero.  The number system is based on units of 10.  Units are kWh. Communication: The SmartLink meter has MODBus COM. Programming Function: With the buttons on the front panel, address, baud rate and passwords can be programmed. Data Sheets: Technical Manual
  • EM735 Modbus Meter

    £59.00 Ex VAT
    EM735 Modbus Smart Energy Meter Main Features & Functions Three phase metering • CE Approved • Three Phase metering, 7 din modules • Accuracy class 1 according to IEC62053-21 • LCD display, 6 integer 2 decimal • Large clear backlight display • Smart communication port, Modbus RTU with 16 bit CRC • Energy consumption LED • Isolate pulse output • Internal transformer • Direct metering up to 100A, transformer metering 1.5(6)A • 27 CT rate can be selected • Optional single-phase model • Can be set through front panel • Memory back-up (EEprom) Data Sheets Manual
  • EM737 CT Smart Energy Meter Three phase metering Main Features and Functions • Standard DIN rail Format (DIN43880) • EN50470-3 Class B. • Import & Export active energy / Import & Export reactive energy • Instant Volt, Amp, Power factor, Frequency, Active power, Reactive power, Apparent power • Isolate pulse output and IR (DIN43864) • LCD display, 6 integer 2 decimal • Large clear backlight display • Internal transformer • 27 CT rate can be selected • Optional single-phase model • RS485 communication port, modbus protocol, IR port • Program by button on the nameplate • Memory back-up (EEprom) • 7 DIN modules • MID approval • The meter is intended to be installed in a Mechanical Environment ‘M1’, with Shock and Vibrations of low significance, as per 2004/22/EC Directive and should be installed in Electromagnetic Environment ‘E2’, as per 2004/22/EC Directive. ** When ordering this product, please order Current Transformers.  ie: 3 phase = 3 CT's. Data Sheets User Manual
  • Kalina is designed as a low cost solution to receive meter readings—via e-mail or collect direct from a web page using an existing broadband connection
    Data Sheets: Technical Datasheet FAQ's Read the FAQ's
  • Card Timing Prepayment Meters - Sports & Leisure Applications
    • Simple to program and functional prepaid ‘Timing Meter’
    • High Quality LCD Display – (Decrementing time displayed)
    • Retains Memory – In the event of loss of power
    • Uses Magnetic Stripe Card To Insert Credits
    • Timing Range (variable) 1 second to 99 days
    • Audit Facility
    • Large Switching capacity up to 100 amps direct
    • Override & End Of Session Warning Facilities
    • Conforms to European Environmental Legislation
    • Time - Calibrated Accuracy
    • Reset Option
    Data Sheets: HE202 - Technical Details HE202 - Installation Instructions FAQ's HE202 FAQ's
  • The HE203e is a card operated prepayment single phase electric meter for domestic use.
    • Simple to program and functional prepaid ‘Timing Meter’
    • High Quality LCD Display – (Decrementing time displayed)
    • Retains Memory – In the event of loss of power
    • Uses Magnetic Stripe Card To Insert Credits
    • Audit Facility
    • Large Switching capacity up to 100 amps direct
    • Override & End Of Session Warning Facilities
    • Conforms to European Environmental Legislation
    • Reset Option
    Data Sheets: HE203E - Technical Details HE203E - Installation Instructions HE203E - Schematic & Wiring Diagram FAQ's: HE203E - Electric FAQ's
  • Card Timing Prepayment Meters - Sports & Leisure Applications
    • Simple to program and functional prepaid ‘Timing Meter’
    • High Quality LCD Display – (Decrementing time displayed)
    • Retains Memory – In the event of loss of power
    • Uses Magnetic Stripe Card To Insert Credits
    • Timing Range (variable) 1 second to 99 days
    • Audit Facility
    • Large Switching capacity up to 125 amps direct
    • Override & End Of Session Warning Facilities
    • Conforms to European Environmental Legislation
    • Time - Calibrated Accuracy
    • Reset Option
    Data Sheets: SC3100 Technical Specifications SC3100PM- Schematic HE203E - 3 Phase Electricity Instructions 3 Phase Contactor - Data Sheet FAQ's: Contact us for further information
  • Converts Utility Meters Into M Bus. Suitable For Electricity - Gas - Oil - Water Meters with a pulsed output Data Sheets: Technical Details Installation Instructions with a Water Meter Installation Instructions - Gas Meter with M-BUS  
  • 'The Tiny' - Single Phase Electricity Meter
    • 100 amps - 230 volts - 50 htz
    • Size Wide 125mm / 4.7/8"
    • High 80mm / 3.1/8"
    • Deep 36mm / 1.50"
    • Proven design and reliability
    • Ofgem/MID Compliant
    • Suitable For Billing Inc PV/Wind Turbines & Heat Pumps
    • Wall Mounted -Manufactured to lSOEN 1036
    • Each meter complete with own Calibration Certificate ('FREE' OF CHARGE)
    Data Sheets: The Tiny - Technical Data Sheet FAQ's: Click Here
  • SCT-T Series Split Core Current Transformer Main Features and Functions • Small Size • Low Cost • High Secondary Turns • Secure Locking Hinge • Maximum continuous primary current 100A to 500AAC • Output: 1A or 5A at rated current • Accuracy : ± 1% 2VA • Indoor or Outdoor use, outdoor type with rubber cover • Insulation Voltage: 600VAC • Maximum Primary Voltage: 5000VAC (Insulated Conductor) • Phase Angle : >2°C at 50% of rated current • Frequency Range: 50Hz to 400Hz • Operating Temperature: - 15°C to 60°C • Leads: 1.0m cable • Output and leads can be customized • Good linearity at very low current Data Sheets User Manual
  • 3 Phase Credit Meter – Wholecurrent – 230/415volts 100amps
    • 40 -100 amp Direct Connected Or CT Operated 100amp +
    • Manufactured to lSOEN1036
    • Size (mm) 170w 90d 253h
    • Ofgem/MID Approved
    • Suitable For Billing Inc PV/Wind Turbines & Heat Pumps
    • Wall mounted - Manufactured to ISOEN 1036
    • Each meter complete with own Calibration Certificate ('FREE' OF CHARGE)
    Data Sheets: SC3100/P Technical Specifications